Wac Track Lighting at best prices.
Plastic Wire Clip
Comes In Pack Of 10
Use To Tack Power Cords Or Joiner Cables Neatly To A Surface
X-connector used to create a four-way connection
Easy to install for power continuity
To be used with WAC Lighting line, line 2.0, and straight edge under cabinet Fixture
Y-connector used to create a three-way connection
Easy to install for power continuity
To be used with WAC Lighting line, line 2.0, and straight edge under cabinet Fixture
Built in on/off switch
Installs at end of a track or remotely
Live end connector (SLE) required to power each track section
ASHRAE 90. 1 and IECC Requirements: The greater of the sum of the maximum rated wattage of the luminaires OR 30 watts per linear ft of track circuit. Current limiters eliminate the need for calculation and testing, and ensures the track system alsways stays in compliance.
California’s Title 24 requirement: The greater of either: The sum of the maximum rated wattage of the luminaires OR 45 watts per linear ft of track circuit. Current limiters eliminate the need for calculation and testing, and ensures the track system alsways stays in compliance.
For use with H Track systems only. Available in a variety of finish options and amperage rating.
ASHRAE 90. 1 and IECC Requirements: The greater of the sum of the maximum rated wattage of the luminaires OR 30 watts per linear ft of track circuit. Current limiters eliminate the need for calculation and testing, and ensures the track system alsways stays in compliance.
California’s Title 24 requirement: The greater of either: The sum of the maximum rated wattage of the luminaires OR 45 watts per linear ft of track circuit. Current limiters eliminate the need for calculation and testing, and ensures the track system alsways stays in compliance.
For use with H Track systems only. Available in a variety of finish options and amperage rating.
1 x 10A – 1200W
Energy code track installations are subject to wattage limitations based upon the size and usage of the space
The Track Current Limiter may be mounted as a standard canopy, used in place of an “I” connector or as a Live-end
ASHRAE 90.1 and IECC Requirements: The greater of the sum of the maximum rated wattage of the luminaires OR 30 watts per linear ft. of track circuit. Current limiters eliminate the need for calculation and testing, and ensures the track system always stays in compliance.
California’s Title 24 requirement: The greater of either: The sum of the maximum rated wattage of the luminaires OR 45 watts per linear ft. of track circuit. Current limiters eliminate the need for calculation and testing, and ensures the track system always stays in compliance.
For use with H Track systems only. Available in a variety of finish options and amperage rating.
1 x 10A – 1200W
Energy code track installations are subject to wattage limitations based upon the size and usage of the space
The Track Current Limiter may be mounted as a standard canopy, used in place of an “I” connector or as a Live-end
1 x 1A – 120W
Energy code track installations are subject to wattage limitations based upon the size and usage of the space
The Track Current Limiter may be mounted as a standard canopy, used in place of an “I” connector or as a Live-end